Control-Plus range
The Control-Plus range incorporates many features of the Value range:
- Compact plug-in control pack.
- Smallest sensor head of its type.
- Extendable area of sensor coverage.
- Programmable sensors.
- Choice of occupancy or absence sensing.
- 0-10V, DSI or DALI options.
- Dimming, daylight linking & daylight dependency available.
- Fully compatible with Flex 7 connection and interconnection systems.
However, it also offers additional advanced options:
- Linking – all Control-Plus sensors can be linked to each other, using a simple, plug-in link lead.
- Emergency test – any Control-Plus control pack can be fitted with a second relay specifically configured to perform an emergency test. The emergency test function can be linked in the same way as all Control-Plus switches and sensors, allowing groups of emergency fittings on different circuits or even all the emergency fittings in a building to be tested with one switch.
- Multiple circuit switching – the second relay can be configured to be sensor controlled and, used with a special connection unit, can separately switch a second group of lights. These can be either occupancy or absence controlled with manual retractive switches. If digital dimming ballasts are used, the dimming function can also be manually switched separately, allowing three independent switch controls.
- Corridor hold units – when any room or area sensor linked to a corridor hold unit detects occupancy (or timing out), the corridor sensors are held On, ensuring an illuminated exit route. Corridor hold units can also be linked together so that a route is held on down escape stairs, through reception areas or to emergency exits.
- Timer units – sensors linked to a timer unit will be held On whilst the timer is on but will revert to sensor control when the timer is off.
- Three-position switch – for positive control of switching On and Off and of dimming up and down.
All of these features can be simply installed on site with no commissioning necessary.
For further details of corridor hold; links to timers or BMS systems; networking of occupancy and switching; an additional relay for emergency testing or creating two and three switch circuits; or other advanced features, see the information leaflets below or contact us to discuss your requirements.
Control-plus range |
Information |
 |
Product overview |
|
|
 |
Introduction to networking sensors |
|
|
Controllers |
Occupancy sensors |
 |
Fnc2000 controller - On/Off |
 |
Fnc2000/E controller - On/Off + integral emergency test |
 |
Fnc4000 controller - Dimming |
 |
Fnc4000/E controller - Dimming with integral emergency test |
Absence sensors (using a 3-position centre off momentary switch) |
 |
Fnc2000/AB controller - On/Off |
 |
Fnc2000/AB/E controller - On/Off + integral emergency test |
 |
Fnc4000/AB controller - Dimming |
 |
Fnc4000/AB/E controller - Dimming + integral emergency test |
Absence sensors (using a 1-way momentary switch) |
 |
Fnc2000/AT controller - On/Off |
|
|
 |
Fnc2000/AT/E controller - On/Off + integral emergency test |
|
|
 |
Fnc4000/AT controller - Dimming |
|
|
 |
Fnc4000/AT/E controller - Dimming + integral emergency test |
|
|
Sensor heads |
Remote control |
 |
Fnh200 - Occupancy |
 |
Frc/set - Set up remote control |
 |
Fnh400 - Occupancy + light detection |
 |
Frc/user - User remote control |
 |
Fnh/slave - Additional occupancy |
|
|